Features
- Low Cost In-Circuit Test
- TestJet Technology
- 2000 Test Point Capability
- Quick-Change Top and Bottom Bed-of-Nails Fixtures
- Fully Integrated CheckSum Windows XP or Windows 2000 Test System Software Environment
Applications
- Loaded Circuit Assemblies
- Through-Hole and SMT Assemblies
- Single and Double-Sided Assemblies
- Individual or Panelized PCBs
- In-System Programming (ISP) with MultiWriter
Analyst ems+ft Overview
Overview
The CheckSum Analyst ems+ft extends the testing power of the Analyst
ems with an integrated functional test subsystem that includes flexible
stimulus, measurement and switching capabilities. It combines in-circuit
test (ICT) with power-up functional test to provide high fault coverage
in a single, low-cost platform that can be customized by the user
to fit a variety of test requirements.
Including industry-unique features such as 250VAC switching and
a fully integrated DMM, function generator and counter-timer, as
well as available relay switching in 50 point increments, the Analyst
ems+ft meets a broad range of functional test requirements from
straightforward power up “board alive” tests to extensive
functional test sequences.
A typical test sequence on the Analyst ems+ft would proceed as
follows:
Power-off in-circuit test (ICT). Typically, test programs are written
such that the test is aborted if any power-off faults are detected.
Apply board power and check critical voltage points including behavior
of powered components such as operational amplifiers.
Perform more extensive functional testing such as checking input/output
parameters.
Solid-state switching in 200-point increments and 50-point relay
switch matrix cards may be mixed in any combination.
Circuits with voltages up to about ±12V will typically employ
solid-state switching and voltages up to 250Vp-p are accommodated
by relay switching. When greater than 40 volts is present at the
UUT during test, the test fixture should be designed with safety
shielding and operator interlocks to help prevent the operator from
coming in contact with the signals.
In most cases functional test can be performed using the same test
fixture as the in-circuit test so that minimal time is spent transferring,
loading and unloading the UUT.
The Analyst ems+ft includes an additional 19 inch rack space, allowing
addition of off-the-shelf measurement/stimulus instruments or programmable
power supplies to meet special requirements.
Download
Analyst ems+ft data sheet and specifications |